Detail Pen TV200/ 220/ 260
Vibration pen TV200/ 220/ 260 # Prompt testing of vibration on the workshop machines.
# For quick checking of unbalance misalignment, bearings and gears
# Guard against mechanical malfunction
# Holding tested value for 40 seconds
# Automatic switch off after 40 seconds
# TV200 is used specially for velocity testing
# TV220 is used specially for displacement testing
# TV260 is used for testing of acceleration, velocity and displacement
Technical specifications
Standard delivery
# Main unit
1
# Protective sheath
1
# Button battery
2
# TIME certificate
1
# Instruction manual
1
# Warranty card
1
Optional accessories
# None
ULTRASONIC FLAW DETECTOR TUD320 # Color TFT display screen with backlight
# Reference waves with different colors can be displayed at the same time
# Curved surface correction: inspection of inner and outer curved surface, auto-correcting the detecting result according to diameter of curved surface
# DGS ( AVG) curve: special key is designed for 2 types of DGS curves: flat-bottom hole and infinite plane.
# Real-time battery power indication, displayed by percentage
# Automatic generation of DAC curve. and 30 points can be recorded at most.adjustable offset curves and gain correction functions are available.
# Three detecting modes: single-probe , dual-probe and transmission;
# Two scanning mode: A and B;
# Two measuring unit: mm/ inch;
# Four Rectify Ways: positive half-wave, negative half-wave, full wave and radio frequency.
# Gate alarming function.
# 10 detecting channels are available with a separate detecting parameter and DAC curve in every channel.
Technical specifications
Items Description
Scanning Range 2.5 mm ~ 5000 mm
Scanning Resolution 0.1mm ( 2.5mm ~ 100mm) 1mm ( 100 mm ~ 5000mm)
Gain Range 0dB ~ 110 dB
D-Delay -20s~ + 3400s
P-Delay 0s~ 99.99s.resolution 0.01s
Sound speed 1000 m/ s~ 9999m/ s
Bandwidth 0.2MHz~ 15MHz( Low0.2~ 1, Mid.0.5~ 4, High 3~ 15)
Vertical linearity error 3%
Horizontal linearity error 0.2%
Dynamic range 32dB
Rectification Positive half wave, negative wave, full wave, and RF
Sensitivity leavings 60dB
Test mode Pulse-echo, dual and through transmission
Pulser Spike excitation pulser
Damping 50ohms, 150ohms and 400ohms
Reject Linear, 0-80% of full screen, variable in steps of 1%
Unit Metric/ inch
Interface RS232
Printer TP UP-NH-S line thermal printer
AC requirements 85-264V AC/ 1.0A, 47-63Hz
Temperature -10~ 40
Humidity 20% ~ 90% RH
Power supply Li battery 4x3.6V 4000mAh
Charging time 4~ 5hours
Weight 1.47kg
Overall dimension 243mmx173 mmx70 mm
Standard delivery
# Main unit
1
# Power adaptor
1
# Neck strap
1
# Cable for probe
2
# Carrying case
1
# Instruction manual
1
# Straight probe
1
# Angle probe
1
# Couplant
1
Optional accessories
# Connecting Cable
# Dataview for communication with PC
# TP UP-NH-S line thermal printer
# Various probes
TUD320 SUDAH DISCONTINUE DENGAN TIPE PENGGANTI TUD310
ULTRASONIC FLAW DETECTOR TUD300.
# Measuring of pitch interval and analyze of echo times;
# Two input methods: angles and K value.
# Auto-calibration of probe and auto-gain.
# Two measuring unit: mm/ inch;
# All built-in software can be up-graded on PC;
# Lock/ unlock the system parameters;
# Equipped with gate setting and alarming function.
# Two measurement displaying mode: type A and type B;
# Freeze/ defreeze waveform and detection parameters;
# Communicating with PC by RS232 port for transferring the measuring data and system parameters;
# 10 detecting channels are available with a separate detecting parameter and DAC curve in every channel.
# Automatic generation of DAC curve, and 30 points can be recorded at most, adjustable offset curves and gain correction functions are available.
# Provided with linear suppressing function, the highest suppressing is 80% of the screen height;
# Memory up to 300 A scanned images, parameters and DAC, and 30000 thickness values.
# Four Rectify Ways: positive half-wave, negative half-wave, full wave and radio frequency.
# Three detecting modes: single-probe , dual-probe ones and transmission;
Technical Specification
Items Description
Scanning Range 2.5 mm ~ 5000 mm
Scanning Resolution 0.1mm ( 2.5mm ~ 100mm) 1mm ( 100 mm ~ 5000mm)
Gain Range 0dB ~ 110 dB
D-Delay -20s~ + 3400s
P-Delay 0s~ 99.99s£ ¬ resolution 0.01s
Sound speed 1000 m/ s~ 9999m/ s
Bandwidth 0.2MHz~ 15MHz( Low0.2~ 1, Mid.0.5~ 4, High 3~ 15)
Vertical linearity error 3%
Horizontal linearity error 0.2%
Dynamic range 32dB
Rectification Positive half wave, negative wave, full wave, and RF
Sensitivity leavings 60dB
Test mode Pulse-echo, dual and through transmission
Pulser Spike excitation pulser
Damping 50ohms, 150ohms and 400ohms
Reject Linear, 0-80% of full screen, variable in steps of 1%
Unit Metric/ inch
Interface RS232
Printer TP UP-NH-S line thermal printer
AC requirements 85-264V AC/ 1.0A, 47-63Hz
Temperature -10~ 40
Humidity 20% ~ 90% RH
Power supply Li battery 4x3.6V 4000mAh
Charging time 4~ 5hours
Weight 1.47kg
Overall dimension 243mmx173 mmx70 mm
Distributor, agent, penjualan, service, perbaikan upgrade system. alat uji, alat laboratorium, alat maintenance, alat inspeksi lapangan, alat quality inspection, alat quality control, alat riset, alat monitoring system, alat preventive maintenance. Jakarta - Indonesia.
TUD300 SUDAH DISCONTINUE DENGAN TIPE PENGGANTI TUD310
Kunjungi Web kami juga di: http: / / www.alatuji.com
Alatuji
Kontak Person: Bpk. Ivan, Ibu Dini, Ibu Rahmah
Hp: 0812 8006 9024, 0817 6700 726, 0816 1740 8927, 021-9529 3259, 0815 907 2797 ( Sri)
Alamat lengkap: Jl. Radin Inten II No. 62
Duren Sawit - Jakarta 13440
Phone: + 62-21 8690 6777, 8690 6771, 8690 6785
Fax: + 62-21 8690 6770
EMAIL : sales@ alatuji.com
Website : www.alatuji.com
Tampilkan Lebih Banyak